Sterowanie analogowe
Combined analog I/O module
Specifications |
FX2N-5A |
||
---|---|---|---|
Analog channels |
Inputs |
4 |
|
Outputs |
1 |
||
Input (resolution) |
Voltage |
-10–10 V (15 bit + sign), -100–100 mV (11 bit + sign) |
|
Current |
-20–20 mA (14 bit + sign), 0/4–20 mA (14 bit) |
||
Output (resolution) |
Voltage |
-10–10 V (12 bit) |
|
Current |
0/4–20 mA (10 bit) |
||
Fullscale overall accuracy |
±0.3–1 %* |
||
Power supply |
5 V DC |
70 mA (from base unit) |
|
24 V DC |
90 mA |
||
Related I/O points |
8 |
||
Weight |
kg |
0.3 |
|
Dimensions (WxHxD) |
mm |
55x90x87 |
|
Order information |
Art. no. |
153740 |
Note: To connect the module to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.
Analog input modules
Specifications |
FX2N-2AD |
FX3U-4AD |
|||
---|---|---|---|---|---|
Applicable for |
Base units FX3G/FX3GC/FX3GE/FX3U/FX3UC |
Base units FX3G/FX3GC/FX3GE/ FX3U/FX3UC/ FX5U/FX5UC |
|||
Analog channels |
Inputs |
2 |
4 |
||
Outputs |
— |
— |
|||
Analog input range |
0–10 V DC/ 0–5 V DC/ 0/4–20 mA |
-10–10 V DC/-20–20 mA/4–20 mA |
|||
Resolution |
Voltage |
2.5 mV, 1.25 mV/ 4 µA (12 bit) |
0.32 mV (16 bit + sign) |
||
Current |
2.5 mV, 1.25 mV/ 4 µA (12 bit) |
1.25 µA (15 bit + sign) |
|||
Fullscale overall accuracy |
±1 % |
±0.3–1 % 1 |
|||
Power supply |
5 V DC |
20 mA (from base unit) |
110 mA (from base unit) |
||
24 V DC |
50 mA (from base unit) |
90 mA |
|||
Related I/O points |
8 |
8 |
|||
Weight kg |
0.3 |
0.2 |
|||
Dimensions (WxHxD) mm |
43x90x87 |
55x90x87 |
|||
Order information Art. no. |
102869 |
169508 |
- Dependent on the ambient temperature
- Please refer to manuals for further details of specification of temperature detectors.Notes: The FX2N-8AD can be configured to accept standard analog inputs as well as selected temperature inputs such as K, T or J type thermocouples.To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a FX3U-4AD to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Analog output modules
Specifications |
FX2N-2DA |
FX3U-4DA |
|
---|---|---|---|
Applicable for |
Base units FX3G/FX3GC/FX3GE/FX3U/FX3UC |
Base units FX3G/FX3GC/FX3GE/FX3U/FX3UC/FX5U/FX5UC |
|
Analog channels |
Inputs |
— |
— |
Outputs |
2 |
4 |
|
Analog output range |
0–10 V DC/0–5 V DC/4–20 mA |
-10–10 V DC/0–20 mA/4–20 mA |
|
Resolution |
Voltage |
2.5 mV (12 bit) |
0.32 mV (16 bit + sign) |
Current |
4 µA (12 bit) |
0.63 µA (15 bit) |
|
Fullscale overall accuracy |
±1 % |
±0.3–0.5 %* |
|
Power supply |
5 V DC |
30 mA (from base unit) |
— |
24 V DC |
85 mA (from base unit) |
160 mA |
|
Related I/O points |
8 |
8 |
|
Weight kg |
0.3 |
0.2 |
|
Dimensions (WxHxD) mm |
43x90x87 |
55x90x87 |
|
Order information Art. no. |
102868 |
169509 |
* Dependent on the ambient temperature
Notes : To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a FX3U-4DA to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Analog I/O module
Specifications |
FX3U-4AD-ADP |
FX3U-4DA-ADP |
|||
---|---|---|---|---|---|
Analog channels |
Inputs |
4 |
— |
||
Outputs |
— |
4 |
|||
Analog range |
0–10 V DC, 4–20 mA |
0–10 V DC, 4–20 mA |
|||
Resolution |
2.5 mV/10 µA (12 bit/11 bit ) |
2.5 mV/4 µA (12 bit) |
|||
Overall accuracy |
±0.5 % */±1 % |
±0.5 % */±1 % |
|||
Power supply |
5 V DC |
15 mA (from base unit) |
15 mA (from base unit) |
||
24 V DC |
40 mA |
150 mA |
|||
Related I/O points |
0 |
0 |
|||
Weight |
kg |
0.1 |
0.1 |
||
Dimensions (WxHxD) |
mm |
17.6x90(106)x89.5 |
17.6x90(106)x89.5 |
||
Order information |
Art. no. |
165241 |
165271 |
* Dependent on the ambient temperature and signal quality
Notes : When connecting the analog adapters to a FX3G, FX3S or FX3U base unit, a communications adapter is required. A direct connection without adapter is possible if these modules are connected to a FX3GC, FX3GE or FX3UC base unit.
Temperature control modules
Specifications |
FX3U-4LC |
FX5-4LC |
||
---|---|---|---|---|
Applicable for |
Base units FX3G, FX3GC, FX3GE, FX3U, FX3UC, FX5U, FX5UC |
Base units FX5U, FX5UC |
||
Analog inputs |
4 (Thermocouple and Pt100 sensors) |
4 (Thermocouple, Pt100 and Pt1000 sensors ) |
||
Compensated temperature range |
°C |
-200–2300 |
-200–2300 |
|
Digital outputs |
4 NPN transistor open collector output points |
4 NPN transistor open collector output points |
||
Resolution |
°C |
0.1 or 1 |
0.1 or 1 |
|
Fullscale overall accuracy |
±0.3–0.7 % (fullscale, dependent on the ambient temperature) |
±0.3–0.7 % (fullscale, dependent on the ambient temperature) |
||
Power supply |
5 V DC |
160 mA (from base unit) |
140 mA (from base unit) |
|
24 V DC |
50 mA |
25 mA |
||
Related I/O points |
8 |
8 |
||
Dimensions (WxHxD) |
mm |
90x90x86 |
60x90x83 |
|
Order information |
Art. no. |
232806 |
312298 |
Notes : To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a FX5U-4LC to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Analog temperature input adapters
Specifications |
FX3U-4AD-TC-ADP |
FX3U-4AD-PT-ADP |
|||||
---|---|---|---|---|---|---|---|
Applicable for |
Base units FX3S, FX3G, FX3GC, FX3GE, FX3U, FX3UC |
Base units FX3S, FX3G, FX3GC, FX3GE, FX3U, FX3UC |
|||||
Analog inputs |
4 (thermocouples, J or K type) |
4 (Pt100) |
|||||
Compensated temperature range °C |
-100–600 (J)/ -100–1000 (K) |
-50–250 |
|||||
Digital outputs |
-1000–6000 (J)/ -1000–10000 (K) |
-500–2500 |
|||||
Resolution °C |
0.3 (J)/0.4 (K) |
0.1 |
|||||
Fullscale overall accuracy |
±0.5 % (fullscale) |
±0.5–1.0 % (fullscale)* |
|||||
Power supply |
5 V DC |
15 mA (from base unit) |
15 mA (from base unit) |
||||
24 V DC |
45 mA |
50 mA |
|||||
Related I/O points |
0 |
0 |
|||||
Weight kg |
0.1 |
0.1 |
|||||
Dimensions (WxHxD) mm |
17.6x90(106)x89.5 |
17.6x90(106)x89.5 |
|||||
Order information Art. no. |
165273 |
165272 |
* Dependent on the ambient temperature
Notes : When connecting the FX3 analog adapters to a FX3G, FX3S or FX3U base unit, a communications adapter is required. A direct connection without adapter is possible if these modules are connected to a FX3GC, FX3GE or FX3UC base unit.