Komunikacja sieciowa
Specifications |
FX2N-32CCL |
||
---|---|---|---|
Module type |
Remote station |
||
Link points per station |
I/O points |
32 |
|
Register |
8 |
||
Max. number of I/O points |
— |
||
Number of connectable modules |
— |
||
Power supply |
5 V DC |
Max. 130 mA (from base unit) |
|
24 V DC |
50 mA |
||
Related I/O points |
8 |
||
Weight |
kg |
0.3 |
|
Dimensions (WxHxD) |
mm |
43x90x87 |
|
Order information |
Art. no. |
102961 |
Notes: To connect this module to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. More informations about CC-Link are available in various other publications from Mitsubishi Electric.
Specifications |
FX3U-CAN |
||
---|---|---|---|
Module type |
CANopen master |
||
CANopen communication standard |
CiA 301 V4.2, CiA 302 V4.1, CiA 305 V2.2 |
||
CANopen Lift application profile mode |
CiA 417 V2.1 |
||
CANopen PLC device profile mode |
CiA 405 V2.0 |
||
Max. number of modules that can be connected to the network |
30 without repeater; 127 with repeater |
||
Station numbers |
1–127 |
||
Supported communication speeds |
kbps |
10, 20, 50, 125, 250, 500, 800, 1000 |
|
Status displays |
RUN, error, power, network status |
||
Power supply |
5 V DC |
290 mA |
|
24 V DC |
— |
||
Related I/O points |
8 |
||
Weight |
kg |
0.2 |
|
Dimensions (WxHxD) |
mm |
43x90x88.7 |
|
Order information |
Art. no. |
252845 |
Notes: To connect this module to a FX3UC/FX3GC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a FX3U-CAN to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Specifications |
FX3U-32DP |
||
---|---|---|---|
Module type |
Slave station |
||
Transmission type |
Bus network |
||
Transmission data |
Max. 144 bytes |
||
Interface |
9-pin D-SUB for Profibus DP |
||
Max. number of slave stations per configuration |
8 |
||
Communication speed |
5 V DC |
Max. 12 Mbit/s |
|
Communication distance |
24 V DC |
Max. 1200 (depends on communication speed) |
|
Communication cable |
Profibus cable with 9-pin D-SUB connector |
||
Related I/O points |
8 |
||
Power supply |
24 V DC/145 mA (from base unit) |
||
Weight |
kg |
0.2 |
|
Dimensions (WxHxD) |
mm |
43x90x89 |
|
Order information |
Art. no. |
194214 |
Note: To connect a FX3U-32DP to a FX3UC/FX3GC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
Specifications |
FX3U-ENET/FX3U-ENET-P502 |
FX5-ENET |
||
---|---|---|---|---|
Applicable for |
Base units FX3G, FX3GC, FX3GE, FX3U, FX3UC |
Base units FX5U, FX5UC |
||
Protocol |
TCP/IP, UDP |
TCP/IP, UDP |
||
Communication mode |
Full-duplex/half-duplex |
Full-duplex/half-duplex |
||
No. of simultaneous open connections |
8 |
8 |
||
Fixed buffer communication |
1023 word x 8 |
1023 word x 8 |
||
Communication with mail server |
SMTP, POP3 |
SMTP, POP3 |
||
Interface |
IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT) |
IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT) |
||
CC-Link IE Field Network Basic |
— |
Master |
||
Connector |
RJ45 |
2xRJ45 |
||
Max. transfer rate |
100 Mbits/s, 10 Mbit/s |
100 Mbits/s, 10 Mbit/s |
||
Max. segment length |
m |
100 |
100 |
|
Cable |
CAT5 STP or 3 STP |
CAT5 STP or 3 STP |
||
Power supply |
5 V DC |
— |
— |
|
24 V DC |
240 mA (from base unit) |
110 mA (from base unit) |
||
Related I/O points |
8 |
8 |
||
Weight |
kg |
0.3 |
0.2 |
|
Dimensions (WxHxD) |
mm |
55x90x87 |
40x90x83 |
|
Order information |
Art. no. |
166086/225142 |
409823 |
Note: To connect this module to a FX3UC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required .
Specifications |
FX3U-64DP-M |
FX5-DP-M |
|
---|---|---|---|
Applicable for |
Base units FX3U, FX3UC |
Base units FX5U, FX5UC |
|
Module type |
Master station |
Master station |
|
Transmission type |
Bus network |
Bus network |
|
Transmission data |
32 byte/slave (normal service mode) 244 byte/slave (extended service mode) |
32 byte/slave (normal service mode) 244 byte/slave (extended service mode) |
|
Interface |
Profibus DP (with 9 pole D-SUB connector) |
Profibus DP (with 9 pole D-SUB connector) |
|
Max. number of master per configuration |
Max. 1 |
Max. 1 |
|
Repeaters |
3 |
3 |
|
Max. number of slaves |
64 |
64 |
|
Communications speed |
Profibus standard |
Profibus standard |
|
Communications distance m |
Max. 1200 (depends on communication speed) |
Max. 1200 (depends on communication speed) |
|
Communication cable |
Profibus cable with 9-pin D-SUB connector |
Profibus cable with 9-pin D-SUB connector |
|
Power supply |
5 V DC |
— |
— |
24 V DC |
Max. 155 mA (from base unit) |
150 mA (from base unit) |
|
Related I/O points |
8 |
8 |
|
Weight |
kg |
0.2 |
0.2 |
Dimensions (WxHxD) |
mm |
43x90x87 |
40x90x85.3 |
Order information |
Art. no. |
166085 |
409822 |
Accessories |
Profibus connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or PROFICON-PLUS-PG, art. no. 140009 |
Profibus connector up to 12 Mbaud: PROFICON-PLUS, art. no. 140008 or PROFICON-PLUS-PG, art. no. 140009 |
Notes : The FX3U-64DP-M can be used in combination with a FX3U or FX3UC base unit only. To connect this module to a FX3UC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
Specifications |
FX2N-64DNET |
|||
---|---|---|---|---|
Module type |
Slave (group 2) |
|||
Node type |
G2 server |
|||
Station numbers |
0–63 points |
|||
Supported communication speeds |
kbps |
125/250/500 |
||
Communication data (open connection) |
Master/ slave |
No. of connections |
1 connection (group 2) |
|
Transfer time-out |
2,000 ms (ACK time-out) |
|||
UCMM client/server |
No. of connections |
63/63 (group 1, 3) |
||
Data length |
Max. 64 bytes per connection |
|||
Communication data (I/O connection) |
Type |
Polling, cyclic, change of state |
||
Data length |
Max. 64 bytes (fragmentation is possible) |
|||
Module ID code |
K 7090 |
|||
Status displays |
Power, module status, network status |
|||
Related I/O points |
8 |
|||
Power supply |
5 V DC |
120 mA |
||
24 V DC |
50 mA |
|||
Weight |
kg |
0.2 |
||
Dimensions (WxHxD) |
mm |
43x90x87 |
||
Order information |
Art. no. |
131708 |
Specifications |
FX3U-485ADP-MB |
||
---|---|---|---|
Interface |
RS485; Modbus® RS485 |
||
Communication speed* |
kbps |
0.3–19.2 |
|
Max. communication distance |
m |
500 |
|
Power supply |
5 V DC |
20 mA (from base unit) |
|
24 V DC |
— |
||
Related I/O points |
0 |
||
Dimensions (WxHxD) |
mm |
17.6x90(106)x74 |
|
Order information |
Art. no. |
206191 |
* The communication method and communication speed vary depending upon the communication type.
Notes : This adapter module can be connected directly (without special adapter) to a base unit of the FX3GC, FX3GE or FX3UC series. To connect this adapter module to a FX3G, FX3S or FX3U base unit, an adapter is required.
Specifications |
FX2N-232IF |
||
---|---|---|---|
Interface |
RS232C with 9 pole D-SUB connector (photocoupler isolation) |
||
Communication speed |
kbps |
0.3–19.2 |
|
Communication distance |
m |
Max. 15 |
|
Communication cable |
Shielded cable |
||
Communication mode |
Full duplex |
||
Protocols |
Non protocol mode/start stop synchronisation |
||
Send and receive buffer |
512 byte each |
||
Format |
7 or 8 bits, parity none/even/odd, stop bits: 1 or 2 |
||
Power supply |
5 V DC |
40 mA (from base unit) |
|
24 V DC |
80 mA |
||
Related I/O points |
8 |
||
Weight |
kg |
0.3 |
|
Dimensions (WxHxD) |
mm |
55x90x87 |
|
Order information |
Art. no. |
66640 |
Note: To connect this module to a FX3UC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required.
Specifications |
FX3U-CAN |
||
---|---|---|---|
Module type |
CANopen master |
||
CANopen communication standard |
CiA 301 V4.2, CiA 302 V4.1, CiA 305 V2.2 |
||
CANopen Lift application profile mode |
CiA 417 V2.1 |
||
CANopen PLC device profile mode |
CiA 405 V2.0 |
||
Max. number of modules that can be connected to the network |
30 without repeater; 127 with repeater |
||
Station numbers |
1–127 |
||
Supported communication speeds |
kbps |
10, 20, 50, 125, 250, 500, 800, 1000 |
|
Status displays |
RUN, error, power, network status |
||
Power supply |
5 V DC |
290 mA |
|
24 V DC |
— |
||
Related I/O points |
8 |
||
Weight |
kg |
0.2 |
|
Dimensions (WxHxD) |
mm |
43x90x88.7 |
|
Order information |
Art. no. |
252845 |
Notes: To connect this module to a FX3UC/FX3GC base unit, an adapter FX2NC-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a FX3U-CAN to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.
Specifications |
FX3U-ENET-ADP |
||
---|---|---|---|
Protocol |
TCP/IP |
||
No. of simultaneous open connections |
1 |
||
Interface |
IEEE802.3u (100BaseTX), IEEE802.3 (10BaseT) |
||
Connector |
RJ45 (to Ethernet), 3 screw terminals (to ground) |
||
Max. transfer rate |
10 Mbit/s, 100 Mbit/s |
||
Cable |
CAT5 STP or 3 STP |
||
Power supply |
5 V DC |
30 mA (from base unit) |
|
24 V DC |
— |
||
Related I/O points |
0 |
||
Weight |
kg |
0.1 |
|
Dimensions (WxHxD) |
mm |
23x90(106)x81.5 |
|
Order information |
Art. no. |
248844 |
Notes : This module can be connected directly (without adapter) to a base unit of the FX3GC or FX3UC series. To connect this module to a FX3G, FX3S or FX3U base unit, an adapter is required.
Specifications |
FX2N-32DP-IF-D |
||
---|---|---|---|
Power supply |
24 V DC (+20 %/-30 %) |
||
Power consumption |
14 W |
||
Internal current consumption |
5 V DC/max. 220 mA (from base unit) |
||
Interface (connectors) |
9-pin D-SUB for Profibus DP, 8-pin Mini-DIN for PC or programming unit FX-10P/FX-20P/FX-30P |
||
Communication speed |
1200 m |
kbps |
9.6/19.2/45.45/93.75 |
1000 m |
kbps |
187.5 |
|
400 m |
kbps |
500 |
|
200 m |
kbps |
1500 |
|
100 m |
kbps |
3000/6000/12000 |
|
Communication distance |
m |
Max. 1200 (depends on communication speed) |
|
Communication cable |
Profibus cable with 9-pin D-SUB connector |
||
Max. number of controllable I/O points |
256 |
||
Weight |
kg |
0.4 |
|
Dimensions (WxHxD) |
mm |
75x98x87 |
|
Order information |
Art. no. |
142763 |