Produkty

Wyłączniki kompaktowe (MCCB) NF
Wyłączniki kompaktowe (MCCB) NF
Wyłączniki niskiego napięcia Wyłączniki kompaktowe
Wyłącznik kompaktowy (MCCB) otwiera i zamyka obwód niskiego napięcia, a następnie automatycznie przerywa prąd zwarciowy (prąd przeciążeniowy lub zwarciowy), aby chronić instalację elektryczną i przewody obwodu.
 

Type/series

WS-V series

NF32-SV

NF63-SV

NF125-SV

NF125-SGV

NF125-SEV

NF160-SGV

NF250-SV

NF250-SGV

NF250-SEV

S series

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

32

63

125

125*

125*

160*

250

250*

250*

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC

600

600

690

690

690

690

690

690

690

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

3

3/4

3/4

3/4

3/4

3/4

3/4

3/4

3/4

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

8/8

8/8

8/8

8/8

8/8

8/8

8/8

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

500 V

2.5/2.5

7.5/7.5

18/18

30/30

30/30

30/30

30/30

30/30

30/30

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

440 V

2.5/2.5

7.5/7.5

25/25

36/36

36/36

36/36

36/36

36/36

36/36

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

400 V

5/5

7.5/7.5

30/30

36/36

36/36

36/36

36/36

36/36

36/36

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

230 V

7.5/7.5

15/15

30/30

85/85

85/85

85/85

85/85

85/85

85/85

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

75x130x68

75/100x130x68

90/120/x130x68

105/140x165x68

105/140x165x68

105/140x165x68

105/140x165x68

105/140x165x68

105/140x165x68

 

Type

   

NF125-LGV

   

NF160-LGV

 

NF250-LGV

 

L series

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

   

125*

   

160*

 

250*

 

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC

   

690

   

690

 

690

 

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

   

3/4

   

3/4

 

3/4

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

   

8/8

   

8/8

 

8/8

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

500 V

   

36/36

   

36/36

 

36/36

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

440 V

   

50/50

   

50/50

 

50/50

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

400 V

   

50/50

   

50/50

 

50/50

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

230 V

   

90/90

   

90/90

 

90/90

 

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

   

105/140x165x68

   

105/140x165x68

 

105/140x165x68

 
 

Type

 

NF63-HV

NF125-HGV

 

NF125-HEV

NF160-HGV

 

NF250-HGV

NF250-HEV

H series

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

 

63

125*

 

125*

160*

 

250*

250*

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC

 

690

690

 

690

690

 

690

690

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

 

3/4

3/4

 

3/4

3/4

 

3/4

3/4

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

 

2.5/2.5

10/8

 

10/8

10/8

 

10/8

10/8

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

500 V

 

7.5/7.5

50/38

 

50/38

50/38

 

50/50

50/50

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

440 V

 

10/8

65/65

 

65/65

65/65

 

65/65

65/65

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

400 V

 

10/8

75/75

 

75/75

75/75

 

75/75

75/75

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

230 V

 

25/19

100/100

 

100/100

100/100

 

100/100

100/100

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

 

75/100x130x68

105/140x165x68

 

105/140x165x68

105/140x165x68

 

105/140x165x68

105/140x165x68

 

Type

   

NF125-RGV

       

NF250-RGV

 

R series

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

   

125*

       

250*

 

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC

   

690

       

690

 

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

   

3

       

3

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

   

       

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

500 V

   

       

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

440 V

   

125/125

       

125/125

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

400 V

   

150/150

       

150/150

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

230 V

   

150/150

       

150/150

 

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

   

105x165x68

       

105x165x68

 
 

Type

   

NF125-UV

       

NF250-UV

 

U series

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

   

125

       

250

 

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC

   

690

       

690

 

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

   

3/4

       

3/4

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

   

10/10

       

15/15

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

500 V

   

200/200

       

200/200

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

440 V

   

200/200

       

200/200

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

400 V

   

200/200

       

200/200

 

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

230 V

   

200/200

       

200/200

 

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

   

105/140x240x68

       

105/140x240x68

 
 

Type

DSN32-SV

DSN63-SV

DSN125-SGV

   

DSN160-SGV

 

DSN250-SGV

 

Disconnectors

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

32

63

125

   

160

 

250

 

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC/DC

600

600

690

   

690

 

690

 

Rated voltage U e [V]

Rated voltage U e [V]

AC (50/60 Hz)/DC

AC (50/60 Hz)/DC

AC (50/60 Hz)/DC

500/250

500/250

690/300

   

690/300

 

690/300

 

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

3

3/4

3/4

   

3/4

 

3/4

 

Max. switching current [A] (breaking)

Max. switching current [A] (breaking)

Max. switching current [A] (breaking)

Max. switching current [A] (breaking)

AC/DC

256/128

504/252

1000/500

   

1280/640

 

2000/1000

 

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

75x130x68

75/120x130x68

105/140x165x68

   

105/140x165x68

 

105/140x165x68

 

a DC on request b In case of solderless terminal, interrupting capacity reduces. * adjustable

 

Type/series

WS series

           

NF400-SEW

NF630-SEW

NF800-SEW

NF1000-SEW

NF1250-SEW

NF1600-SEW

S series

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

400*

630*

800*

1000*

1250*

1600*

S series

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC

690

690

690

690

690

690

S series

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

3/4

3/4

3/4

3/4

3/4

3/4

S series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

10/10 b

10/10

10/10

25/13

25/13

25/13

S series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

500 V

30/30 b

30/30

30/30

65/33

65/33

65/33

S series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

440 V

42/42 b

42/42

42/42

85/43

85/43

85/43

S series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

400 V

50/50 b

50/50

50/50

85/43

85/43

85/43

S series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

230 V

85/85 b

85/85

85/85

125/63

125/63

125/63

S series

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

140/185x257x103

140/185x257x103

210/280x275x103

210/280x406x140

210/280x406x140

210/280x406x140

 

Type

NF400-HEW

NF630-HEW

NF800-HEW

     

H series

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

400*

630*

800*

     

H series

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC

690

690

690

     

H series

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

3/4

3/4

3/4

     

H series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

10/10

15/15

15/15

     

H series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

500 V

50/50

50/50

50/50

     

H series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

440 V

65/65

65/65

65/65

     

H series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

400 V

70/70

70/70

70/70

     

H series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

230 V

100/100

100/100

100/100

     

H series

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

140/185x257x103

140/185x257x103

210/280x275x103

     
 

Type

NF400-REW

NF630-REW

NF800-REW

     

R series

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

400*

630*

800*

     

R series

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC

690

690

690

     

R series

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

3

3

3

     

R series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

15/10

20/15

20/15

     

R series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

500 V

70/35

70/35

70/35

     

R series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

440 V

125/63

125/63

125/63

     

R series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

400 V

125/63

125/63

125/63

     

R series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

230 V

150/75

150/75

150/75

     

R series

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

140x257x103

140x257x103

210x275x103

     
 

Type

NF400-UEW

 

NF800-UEW

     

U series

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

400*

 

800*

     

U series

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC

690

 

690

     

U series

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

3/4

 

3/4

     

U series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

690 V

35/35

 

35/35

     

U series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

500 V

170/170

 

170/170

     

U series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

440 V

200/200

 

200/200

     

U series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

400 V

200/200

 

200/200

     

U series

Rated breaking capacity [kA] ( I cu / I cs )

IEC 947-2 EN 60 947-2 VDE 0660

IEC 947-2 EN 60 947-2 VDE 0660

AC a (50/60 Hz)

230 V

200/200

 

200/200

     

U series

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

140/280x297/322x200

 

210/280x322x200

     
 

Type

DSN400-SW

DSN630-SW

DSN800-SW

DSN1000-SW

DSN1250-SW

DSN1600-SW

Disconnectors

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

Rated current I n max. [A]

400

630

800

1000

1250

1600

Disconnectors

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

Rated insulation voltage U i [V]

AC/DC

690

690

690

660

660

660

Disconnectors

Rated voltage U e [V]

Rated voltage U e [V]

AC (50/60 Hz)/DC

AC (50/60 Hz)/DC

AC (50/60 Hz)/DC

690/250

690/250

690/250

660/250

660/250

660/250

Disconnectors

Number of poles

Number of poles

Number of poles

Number of poles

Number of poles

3/4

3/4

3/4

3/4

3/4

3/4

Disconnectors

Max. switching current [A] (breaking)

Max. switching current [A] (breaking)

Max. switching current [A] (breaking)

Max. switching current [A] (breaking)

AC/DC

3200/1600

5040/2520

6400/3200

8000/14000

10000/5000

12800/6400

Disconnectors

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

Dimensions WxHxD

[mm]

140/185x257x103

140/185x257x103

210/280x275x103

210/280x406x140

210/280x406x140

210/280x406x140

* adjustable

 

Skontaktuj się z nami

Ta strona internetowa chroni twoją prywatność poprzez przestrzeganie EU General Data Protection Regulation (RODO). Nie wykorzystamy Twoich danych w żadnym celu, na który nie wyrażasz zgody. Prosimy o zgodę na korzystanie z anonimowych danych, aby poprawić jakość korzystania z naszej witryny. Polityka cookies