Styczniki nieodwracające

Styczniki nieodwracające

Styczniki i rozruszniki silnikowe Styczniki
Nadają się do włączania i wyłączania silników.
Modele standardowe spełniają normy japońskie i międzynarodowe.

 

 

Specifications

S-T10 AC_ _ _V 1A

S-T10 AC_ _ _V 1B

Rated data

Applicable standard

 

All types: IEC60947-4-1, EN60947-4-1, JIS C8201-4-1

All types: IEC60947-4-1, EN60947-4-1, JIS C8201-4-1

Rated insulation voltage

V

All types: 690

All types: 690

Rated impulse withstand voltage

kV

All types: 6

All types: 6

Rated frequency

Hz

All types: 50/60

All types: 50/60

Pollution degree

 

All types: 3

All types: 3

Rated operational power (current) Category AC-3 (Three-phase squirrel-cage motor load, standard responsibility)

220–240 V

kW (A)

2.5 (11)

2.5 (11)

380–440 V

kW (A)

4 (9)

4 (9)

500 V

kW (A)

4 (7)

4 (7)

690 V

kW (A)

4 (5)

4 (5)

Rated operational power (current) Category AC-4 (Three-phase squirrel-cage motor load, inching responsibility)

220–240 V

kW (A)

1.5 (8)

1.5 (8)

380–440 V

kW (A)

2.2 (6)

2.2 (6)

500 V

kW (A)

2.7 (6)

2.7 (6)

Rated operational power (current) Category AC-1 (Resistance, heater load)

100–240 V

kW (A)

20

20

380–440 V

kW (A)

11

11

Conventional free air thermal current Ith

A

20

20

Minimum applicable load level

 

All types: 48 V 200 mA

All types: 48 V 200 mA

Auxiliary contact rating

Contact arrangement

Standard

 

1 NO

1 NC

Max. number of additional options a

Front clip-on

pcs.

1

1

Side clip-on

pcs.

2

2

Rated operational current (Category AC-15 : Alternating current coil load)

120 V

A

6

6

240 V

A

3

3

Rated operational current (Category DC-13 : Direct current coil load)

24 V

A

3

3

110 V

A

0.6

0.6

Conventional free air thermal current Ith

A

10

10

Minimum applicable load level

 

All types: 20 V 3 mA

All types: 20 V 3 mA

Performance

Mechanical durability [ten thousand times]

All types: 1,000

All types: 1,000

Electrical durability [ten thousand times]

Please refer to the Electrical durability curve

Please refer to the Electrical durability curve

Switching frequency [times/hour]

Category AC-3

1800

1800

Category AC-4

300

300

Category AC-1

1200

1200

Coil consumption (at rated coil voltage) c

Inrush

(VA)

45

45

Sealed

(VA)

7

7

Watts

(W)

2.2

2.2

Mechanical data

Dimensions (WxHxD)

mm

36x75x78

36x75x78

 

Order information

AC 24 V

Art. no.

279140

279197

AC 48 V

279141

279198

AC 100 V

279142

279199

AC 200 V

279143

279200

AC 300 V

279144

279201

AC 400 V

279195

279202

AC 500 V

279196

279203

 

Specifications

 

S-T35 AC_ _ _V

S-T50 AC_ _ _V

Rated data

Applicable standard

All types: IEC60947-4-1, EN60947-4-1, JIS C8201-4-1

All types: IEC60947-4-1, EN60947-4-1, JIS C8201-4-1

Rated insulation voltage

690

690

Rated impulse withstand voltage

kV

All types: 6

All types: 6

Rated frequency

Hz

All types: 50/60

All types: 50/60

Pollution degree

All types: 3

All types: 3

Rated operational power (current) Category AC-3 (Three-phase squirrel-cage motor load, standard responsibility)

220–240 V

kW (A)

11( 40)

15( 55)

380–440 V

kW (A)

18.5( 40)

22( 48)

500 V

kW (A)

18.5( 32)

25( 38)

690 V

kW (A)

15( 17)

22( 26)

Rated operational power (current) Category AC-4 (Three-phase squirrel-cage motor load, inching responsibility)

220–240 V

kW (A)

5.5( 26)

7.5( 35)

380–440 V

kW (A)

11( 24)

15( 32)

500 V

kW (A)

11( 17)

15( 24)

Rated operational power (current) Category AC-1 (Resistance, heater load)

100–240 V

A

60

80

380–440 V

A

60

80

Conventional free air thermal current Ith

A

60

80

Minimum applicable load level

All types: 48 V 200 mA

All types: 48 V 200 mA

Auxiliary contact rating

Contact arrangement

Standard

2NO+2NC

2NO+2NC

Max. number of additional options

Front clip-on pcs.

1

1

Side clip-on pcs.

2

2

Rated operational current (Category AC-15 : Alternating current coil load)

120 V AC

6

6

240 V AC

3

3

Rated operational current (Category DC-13 : Direct current coil load)

24 V DC

3

3

110 V DC

0.6

0.6

Conventional free air thermal current Ith

[A]

10

10

Minimum applicable load level

All types: 20 V 3 mA

All types: 20 V 3 mA

Performance

Mechanical durability [ten thousand times]

1000

1000

Electrical durability

Please refer to the Electrical durability curve

Please refer to the Electrical durability curve

Switching frequency [times/hour]

Category AC-3

1800

1200

Category AC-4

300

300

Category AC-1

1200

1200

Coil consumption (at rated coil voltage)

Inrush

(VA)

110

110

Sealed

(VA)

10

10

Watts

(W)

3.8

3.8

Mechanical data

Dimensions (WxHxD)

mm

75x89x91

75x89x91

 

Order Information

AC 24 V

Art. no.

298658

298665

AC 48 V

298661

298668

AC 100 V

298656

298663

AC 200 V

298657

298664

AC 300 V

298659

298666

AC 400 V

298660

298667

AC 500 V

298662

298669

 

Skontaktuj się z nami