Styczniki nieodwracające
Modele standardowe spełniają normy japońskie i międzynarodowe.
|
Specifications |
S-T10 AC_ _ _V 1A |
S-T10 AC_ _ _V 1B |
||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Rated data |
||||||||||||
|
Applicable standard |
All types: IEC60947-4-1, EN60947-4-1, JIS C8201-4-1 |
All types: IEC60947-4-1, EN60947-4-1, JIS C8201-4-1 |
||||||||||
|
Rated insulation voltage |
V |
All types: 690 |
All types: 690 |
|||||||||
|
Rated impulse withstand voltage |
kV |
All types: 6 |
All types: 6 |
|||||||||
|
Rated frequency |
Hz |
All types: 50/60 |
All types: 50/60 |
|||||||||
|
Pollution degree |
All types: 3 |
All types: 3 |
||||||||||
|
Rated operational power (current) Category AC-3 (Three-phase squirrel-cage motor load, standard responsibility) |
220–240 V |
kW (A) |
2.5 (11) |
2.5 (11) |
||||||||
|
380–440 V |
kW (A) |
4 (9) |
4 (9) |
|||||||||
|
500 V |
kW (A) |
4 (7) |
4 (7) |
|||||||||
|
690 V |
kW (A) |
4 (5) |
4 (5) |
|||||||||
|
Rated operational power (current) Category AC-4 (Three-phase squirrel-cage motor load, inching responsibility) |
220–240 V |
kW (A) |
1.5 (8) |
1.5 (8) |
||||||||
|
380–440 V |
kW (A) |
2.2 (6) |
2.2 (6) |
|||||||||
|
500 V |
kW (A) |
2.7 (6) |
2.7 (6) |
|||||||||
|
Rated operational power (current) Category AC-1 (Resistance, heater load) |
100–240 V |
kW (A) |
20 |
20 |
||||||||
|
380–440 V |
kW (A) |
11 |
11 |
|||||||||
|
Conventional free air thermal current Ith |
A |
20 |
20 |
|||||||||
|
Minimum applicable load level |
All types: 48 V 200 mA |
All types: 48 V 200 mA |
||||||||||
|
Auxiliary contact rating |
||||||||||||
|
Contact arrangement |
Standard |
1 NO |
1 NC |
|||||||||
|
Max. number of additional options a |
Front clip-on |
pcs. |
1 |
1 |
||||||||
|
Side clip-on |
pcs. |
2 |
2 |
|||||||||
|
Rated operational current (Category AC-15 : Alternating current coil load) |
120 V |
A |
6 |
6 |
||||||||
|
240 V |
A |
3 |
3 |
|||||||||
|
Rated operational current (Category DC-13 : Direct current coil load) |
24 V |
A |
3 |
3 |
||||||||
|
110 V |
A |
0.6 |
0.6 |
|||||||||
|
Conventional free air thermal current Ith |
A |
10 |
10 |
|||||||||
|
Minimum applicable load level |
All types: 20 V 3 mA |
All types: 20 V 3 mA |
||||||||||
|
Performance |
||||||||||||
|
Mechanical durability [ten thousand times] |
All types: 1,000 |
All types: 1,000 |
||||||||||
|
Electrical durability [ten thousand times] |
Please refer to the Electrical durability curve |
Please refer to the Electrical durability curve |
||||||||||
|
Switching frequency [times/hour] |
Category AC-3 |
1800 |
1800 |
|||||||||
|
Category AC-4 |
300 |
300 |
||||||||||
|
Category AC-1 |
1200 |
1200 |
||||||||||
|
Coil consumption (at rated coil voltage) c |
Inrush |
(VA) |
45 |
45 |
||||||||
|
Sealed |
(VA) |
7 |
7 |
|||||||||
|
Watts |
(W) |
2.2 |
2.2 |
|||||||||
|
Mechanical data |
||||||||||||
|
Dimensions (WxHxD) |
mm |
36x75x78 |
36x75x78 |
|||||||||
|
Order information |
AC 24 V |
Art. no. |
279140 |
279197 |
||||||||
|
AC 48 V |
279141 |
279198 |
||||||||||
|
AC 100 V |
279142 |
279199 |
||||||||||
|
AC 200 V |
279143 |
279200 |
||||||||||
|
AC 300 V |
279144 |
279201 |
||||||||||
|
AC 400 V |
279195 |
279202 |
||||||||||
|
AC 500 V |
279196 |
279203 |
||||||||||
|
Specifications |
|
S-T35 AC_ _ _V |
S-T50 AC_ _ _V |
||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Rated data |
|||||||||||||||
|
Applicable standard |
All types: IEC60947-4-1, EN60947-4-1, JIS C8201-4-1 |
All types: IEC60947-4-1, EN60947-4-1, JIS C8201-4-1 |
|||||||||||||
|
Rated insulation voltage |
690 |
690 |
|||||||||||||
|
Rated impulse withstand voltage |
kV |
All types: 6 |
All types: 6 |
||||||||||||
|
Rated frequency |
Hz |
All types: 50/60 |
All types: 50/60 |
||||||||||||
|
Pollution degree |
All types: 3 |
All types: 3 |
|||||||||||||
|
Rated operational power (current) Category AC-3 (Three-phase squirrel-cage motor load, standard responsibility) |
220–240 V |
kW (A) |
11( 40) |
15( 55) |
|||||||||||
|
380–440 V |
kW (A) |
18.5( 40) |
22( 48) |
||||||||||||
|
500 V |
kW (A) |
18.5( 32) |
25( 38) |
||||||||||||
|
690 V |
kW (A) |
15( 17) |
22( 26) |
||||||||||||
|
Rated operational power (current) Category AC-4 (Three-phase squirrel-cage motor load, inching responsibility) |
220–240 V |
kW (A) |
5.5( 26) |
7.5( 35) |
|||||||||||
|
380–440 V |
kW (A) |
11( 24) |
15( 32) |
||||||||||||
|
500 V |
kW (A) |
11( 17) |
15( 24) |
||||||||||||
|
Rated operational power (current) Category AC-1 (Resistance, heater load) |
100–240 V |
A |
60 |
80 |
|||||||||||
|
380–440 V |
A |
60 |
80 |
||||||||||||
|
Conventional free air thermal current Ith |
A |
60 |
80 |
||||||||||||
|
Minimum applicable load level |
All types: 48 V 200 mA |
All types: 48 V 200 mA |
|||||||||||||
|
Auxiliary contact rating |
|||||||||||||||
|
Contact arrangement |
Standard |
2NO+2NC |
2NO+2NC |
||||||||||||
|
Max. number of additional options |
Front clip-on pcs. |
1 |
1 |
||||||||||||
|
Side clip-on pcs. |
2 |
2 |
|||||||||||||
|
Rated operational current (Category AC-15 : Alternating current coil load) |
120 V AC |
6 |
6 |
||||||||||||
|
240 V AC |
3 |
3 |
|||||||||||||
|
Rated operational current (Category DC-13 : Direct current coil load) |
24 V DC |
3 |
3 |
||||||||||||
|
110 V DC |
0.6 |
0.6 |
|||||||||||||
|
Conventional free air thermal current Ith |
[A] |
10 |
10 |
||||||||||||
|
Minimum applicable load level |
All types: 20 V 3 mA |
All types: 20 V 3 mA |
|||||||||||||
|
Performance |
|||||||||||||||
|
Mechanical durability [ten thousand times] |
1000 |
1000 |
|||||||||||||
|
Electrical durability |
Please refer to the Electrical durability curve |
Please refer to the Electrical durability curve |
|||||||||||||
|
Switching frequency [times/hour] |
Category AC-3 |
1800 |
1200 |
||||||||||||
|
Category AC-4 |
300 |
300 |
|||||||||||||
|
Category AC-1 |
1200 |
1200 |
|||||||||||||
|
Coil consumption (at rated coil voltage) |
Inrush |
(VA) |
110 |
110 |
|||||||||||
|
Sealed |
(VA) |
10 |
10 |
||||||||||||
|
Watts |
(W) |
3.8 |
3.8 |
||||||||||||
|
Mechanical data |
|||||||||||||||
|
Dimensions (WxHxD) |
mm |
75x89x91 |
75x89x91 |
||||||||||||
|
Order Information |
AC 24 V |
Art. no. |
298658 |
298665 |
|||||||||||
|
AC 48 V |
298661 |
298668 |
|||||||||||||
|
AC 100 V |
298656 |
298663 |
|||||||||||||
|
AC 200 V |
298657 |
298664 |
|||||||||||||
|
AC 300 V |
298659 |
298666 |
|||||||||||||
|
AC 400 V |
298660 |
298667 |
|||||||||||||
|
AC 500 V |
298662 |
298669 |
|||||||||||||