Zasilacz
Specifications |
R61P |
R62P |
R63P |
R63RP |
R64P * |
R64RP |
||
---|---|---|---|---|---|---|---|---|
Input voltage |
(+10 %, -15 %) |
V AC |
100–240 (85–264) |
100–240 (85–264) |
— |
— |
100–240 (85–264) |
100–240 (85–264) |
(+30 %, -35 %) |
V DC |
— |
— |
24 (15.6–31.2) |
24 (19.2–31.2) |
— |
— |
|
Input frequency |
Hz |
50/60 (±5 %) |
50/60 (±5 %) |
— |
— |
50/60 (±5 %) |
50/60 (±5 %) |
|
Inrush current |
20 A within 8 ms |
20 A within 8 ms |
100 A within 1 ms |
100 A within 1 ms |
20 A within 8 ms |
20 A within 8 ms |
||
Max. input apparent power VA |
130 |
120 |
— |
— |
160 |
160 |
||
Max. input power W |
— |
— |
50 |
50 |
— |
50 |
||
Rated output current |
5 V DC |
A |
6.5 |
3.5 |
6.5 |
6.5 |
9 |
9 |
24 V DC ±10 % |
A |
— |
0.6 |
— |
— |
— |
— |
|
Overcurrent protection |
5 V DC |
A |
≥7.1 |
≥3.8 |
≥7.1 |
≥7.1 |
≥10.0 |
≥10.0 |
24 V DC |
A |
— |
≥0.66 |
— |
— |
— |
— |
|
Overvoltage protection |
5 V DC |
V |
5.5–6.6 |
5.5–6.6 |
5.5–6.6 |
— |
5.5–6.6 |
— |
Efficiency |
≥76 % |
≥76 % |
≥70 % |
≥70 % |
≥76 % |
≥76 % |
||
Insulation withstand voltage |
2830 V AC, 1 min. |
2830 V AC, 1 min. |
510 V AC, 1 min. |
510 V AC, 1 min. |
2830 V AC, 1 min. |
2830 V AC, 1 min. |
||
Max. compensation time at power failure |
ms |
20 |
20 |
10 |
10 |
20 |
20 |
|
Power indicator |
All modules possess a power LED display. |
|||||||
Terminal screw size |
M4 (M3.5 for +24V and 24G terminals of the R62P |
|||||||
Applicable wire size |
mm 2 |
0.75–2 |
0.75–2 |
0.75–2 |
0.75–2 |
0.75–2 |
0.75–2 |
|
Weight |
kg |
0.41 |
0.45 |
0.41 |
0.41 |
0.46 |
0.46 |
|
Dimensions (WxHxD) |
mm |
54.6x106x110 |
54.6x106x110 |
54.6x106x110 |
54.6x106x110 |
54.6x106x 11 |
54.6x106x110 |
|
Order information Art. no. |
279581 |
285507 |
279582 |
308710 |
285508 |
301649 |
* Redundant power supply