Moduł master IO-Link
Specifications |
ME1IOL6-L |
||
---|---|---|---|
Nbr. of channels |
6 |
||
Channel configuration |
IO-Link, digital output, digital input, disabled |
||
IO-Link |
Rated load voltage |
24 V DC |
|
Rated output current |
15 mA |
||
Sensor/actuator power supply |
200 mA |
||
Digital input |
Common point |
Positive |
|
Rated load voltage |
24 V DC |
||
Rated input current |
5 mA |
||
Input filter |
200 µs |
||
Digital output |
Rated load voltage |
24 V DC |
|
Output type |
Source |
||
Rated output current |
In total max. 215 mA |
||
Actuator supply |
In total max. 215 mA |
||
Protective functions |
Overcurrent, overload, short circuit |
||
Occupied I/O points |
32 |
||
Connection terminal |
18-point removable terminal block with screws |
||
Applicable cables |
Cable type |
Unshielded cable |
|
Max. lenght |
20 m |
||
Cross-section |
0.3–0.75 mm 2 |
||
External power consumption |
Voltage |
24 V DC (+20 %, -15 %) |
|
Current |
Max. 1.7 A |
||
Weight |
kg |
0.18 |
|
Dimensions (WxHxD) |
mm |
28.5x90x117 |
|
Order information Art. no. |
245825 |